Fabric moisture permeability tester

    Traffic : 0
    Edit time : 2022-05-26
    Relevant tags : Protective clothing testing instruments

    Fabric moisture permeability tester

    [Meet the criteria] GB / T12704 ASTME96 JISL1099 BS7209 et al.

    GB / T12704-91 Determination of fabric moisture cup / Method A

    American Standard ASTM E96-00 The Standard Test Methods for Water Vapor Transmission of Materials Hygroscopic Method

    British Standard BS7209-1990 Hygroscopic Method

    [service environment]

    1. Ambient temperature: 15~30

    2. Relative humidity: less than 80%RH

    3. Power supply: 220V ± 5% 50Hz

    4. The instrument shall require grounding protection

    5. The instrument of the placed, more than 30 cm away from obstacles.

    透湿量.jpg 

    [technical parameter]

    1. Adjustable temperature / control accuracy: 20~50℃ ± 0.5;

    2. Adjustable humidity / relative humidity: 40~95% ± 2% RH;

    3. Standard test temperature and humidity: 23℃± 0.550% ± 2% RH;

    38℃±0.5   50%±2% RH

    38℃±0.5   90%±2% RH

    20℃±0.5   65%±2% RH

    4. Moisture transmission indoor wind speed: 0.02~0.8m/s

    5. Wind speed adjustment mode: manual adjustment of the touch screen menu;

    6. Number of moisture-permeable cup frame floors: the second floor;

    7. Number of moisture permeable cups: 6 in single layer; 18 in; (national standard, American standard and British standard matching);

    8. Rotation speed of the water-permeable cup frame: 5rpm / min;

    9. Power supply: AC220V± 10%;

    10. Power: 4.5KW;

    11. Overall dimension: 8506801750mm;

    12. Net weight: 300Kg.

     

    To be used:

    The moisture permeability tester is used to test the moisture permeability of various coating fabrics, composite fabrics, composite film, plastic film, exchange film and other materials, and is commonly used to detect medical protective clothing.

    applied code:

    GB/T12704ASTM E96JISL1099BS 7209

    Technical indexes of moisture permeability tester:

    1. Adjustable temperature control accuracy: 20~50℃± 0.1℃;

    2. Adjustable humidity Relative humidity: 40~95% ± 1%RH

    3. Standard test temperature and humidity:

    30℃± 0.5℃ 23℃± 0.2℃ (water temperature); 23℃± 0.5℃ 50% ± 2%RH;

    20℃±0.5℃65%±2%RH38℃±0.5℃50%±2%RH

    38℃±0.5℃90%±2%RH40℃±0.5℃50%±2%RH

    40℃±0.5℃90%±2%RH

    4. Wind speed range: 0.02~0.8m/s

    5. Wind speed adjustment mode: automatic adjustment and manual adjustment;

    6. Number of moisture-permeable cup frame layers: three layers;

    7. Number of moisture permeable cups: 18 cups on the second floor (national standard, American standard, British standard matching) + daily standard potassium acetate method 6 on the first floor;

    8. Rotation speed of the water-permeable cup holder: 2rpm / min, 5rpm / min is adjustable;

    9. Power supply: AC220V± 10%, power: 4KW.

    technical feature:

    1. The refrigeration system adopts the French Taikang refrigeration unit to ensure the stable operation of the whole machine for a long time;

    2. Adopt the imported temperature and humidity sensor from Switzerland to ensure the accuracy of the temperature and humidity in the experimental chamber;

    3. Using the industrial color touch screen operation, with the menu display in Both Chinese and English;

    4. Adopt the function of automatic water filling, convenient for testing, suitable for long-term test needs;

    5. The temperature and humidity recorded every minute can be queried in real time and connected to the printer print output;

    6. Adopt three layers of test samples, with 9 test cups per each layer, which greatly increases the number of single test samples, reduces the operating cost of users, and improves the efficiency;

    7. The test sample cup is equipped with small doors to reduce the impact of the test sample on the test environment after opening the door, and shorten the stability time again;

    8. After closing the test cabin door in GB / T12704 ~ Article 5.1.1 of 2009, the balance must be reached again within 3 minutes;

    9. The rotary sample is placed and the test is uniform than the fixed specimen.

     


    Shanghai chengsi intelligent technology co., LTD

    Contact: Mr. Gao

    Phone: 17701637746

    Phone: 19821311892

    Address: no. 265, east street, zhuangxing town, fengxian district, Shanghai

    备案号:沪ICP备19009154号-12

    万能耐磨试验机