Suture needle triangle needle edge cutting force tester

    Traffic : 0
    Edit time : 2022-05-31
    Relevant tags : 松江Medical device testing instruments

    Suture needle triangle needle edge cutting force tester 

    Use a 7-inch LCD display screen, with the Chinese menu display.The menu on the LCD screen is controlled by the keyboard, which automatically loads the cutting force, automatically outputs the data report, and prints the test data onboard.Nominal specification, test load, printing, test, uplink, downlink, time, and calibration.

    operative norm:

    The needle blade cutting force tester is fully in line with the standard design and manufacture of YY0166 YY0166 and YY0043 Medical Suture Needles.

    technical parameter:
    Load rate: 10 mm/s (optional);

    Force value error of the instrument: not greater than 0.98N

    Start sensation of the instrument: not greater than 1.86 N.

    Full load of 29.4N
    Nomspecification: 0.2~1.4mm;
    Printing method: the average test data and its total average and deviation value can be printed;
    Net weight: 8kg,
    Overall Dimensions: 270410290 (mm)

    Cture angle: 180°;

    817a7a1280880d3ee285d5979f88564.png 

    Part of the list:
    1. One host machine 2. One set of printing paper 3
    7. Instruments * upgrade services according to national standards

     

    test procedure:

    The schematic value error of the instrument shall not be greater than 0.98 N.

    The instrument should have a correction level and shock-proof device, and the needle clip should be adjusted and stable during use.

    The transmission of the instrument shall be sensitive and reliable, and the pointer shall stop automatically when the suture is cut.

    Suture line requirements

    Sutures is 4-0 coated twisted medical wire, its performance requirements shall meet the requirements of XY0167-2005.

    The suture surface shall be clean and dry without knotted defects.

    Sutures shall not exceed the service period specified in the standard.

    testing program

    Suture needles, instruments, and sutures were placed in a 22℃ x 2g ℃ environment for at least 1 h and tested under the same conditions.Position the suture needle (one side of the suture needle plane) down on the fixture, fold the suture from 9 c m to 10 c m, and then hang it on the upper fixture to U-shape, and insert the front section of the triangular needle blade (1 / 3 of the total length of the triangular blade mouth) for cutting.When the triangular edge cuts the seam line, the scale indicated by the pointer is the cutting force of the triangular edge.

    Press the work control switch button to restore the pointer to the ether.

    Turn the needle clamp for 180° to determine the flat edge cutting force of the other side of the suture needle with the same test method

    The two-plane blade edges of each triangular suture needle were cut once, and the arithmetic average value was taken.

     