    Thermal protection performance tester

    Thermal protection performance tester is used to detect the thermal protective performance of protective clothing, safety shoes, gloves, helmet exterior surface, and to detect the thermal protection performance of materials under the action of established heat radiation source.The sample is exposed to a heat source with the specified heat radiation energy, and the sensor signal is collected at high speed. The TPP value is calculated by the software, and the report is provided in the form of Excel or Word.

    750 (4).png

    First, product characteristics

    1. The test instrument shall include the specimen seat assembly, bracket, heat source, shield, sensor assembly, recorder and gasket, and shall also have gas source, gas flow meter, burner and sensor;

    2. Mobile stainless steel protective plate can block the flame and reduce the test error;

    3,2 Meker burner at 45 degrees, with 9 quartz pipes to provide standard convection heat source;

    4, Meker burner diameter of 38mm, inner hole diameter of 5 / 16 inches, can provide 800-1200 BUT heat output, burner port is metal mesh structure, burner lower air valve is adjustable, can adjust the air and gas mix ratio;

    5,9 T150 quartz IR tube arrays that provide a heat radiation flux of 13-40 k W/m2 ± 4 kW / m2;

    6. Under the thermal radiation of quartz infrared tube, the total heat flux can be set to 83 k W/m2 ± 2 kW / m2;

    7. Calibrated heat flow meter is water-cooled with working range of 0-100 K W/m2 and maximum use range of 150%;

    8. The response time of the heat flowmeter is less than 200ms, the radiability is greater than 0.95, and the output signal within the operating range is greater than 5mv;

    9. Copper disk calorimeter device, which can be used to detect convective heat and radiation heat, and can detect the back temperature of the sample;

    10, Equipped with a heat radiation flux display instrument, even if the heat flux value is displayed;

    11. Provide calibration reports dating back to NIST;

    12, The rotor flowmeter can adjust the combustion gas flow with an accuracy of ± 2% and a range greater than 3 L/min;

    13. Pointer pressure gauge, the intake pressure can be adjusted by the pressure reduction valve, whose measuring range is 0-15psi;

    14. Quarter rotary plug, which can manually cut off the combustible gas;

    15. The resolution of the temperature acquisition system is 0.1C°, and the accuracy is ± 0.75°C;

    16. The data acquisition speed of the automatic data acquisition system is second / 0.05 seconds, and provides cold end compensation for the measurement data of thermocouples;

    17. Equipped with a computer and a printer, equipped with the standard test software, to provide the standard test curve.

    Second, meet the standards

    NFPA 1971, NFPA 2112, ASTM D4018, GB 8965.1-2009, ISO 12749, ISO 17492, GB 8695.1.

     