Introduction to manual surface tensiometer
The main technical indicators of this table interface tensiometer are still up to the standard of automatic basic model. In addition to the automatic lifting and lowering of the test platform of the instrument (including fast and fine tuning second gear), the testing process is still automatic testing, calculation and display. Under the premise of ensuring technical indicators, it is an economical and practical product.
Product features:
Compared with other surface tensimeters, manual lifting surface tensimeters include but are not limited to the following advantages:
* sensor sensitive response, high precision, liquid crystal display;
* automatic reading of surface tension balance value;
* manual lifting with fast and fine tuning second gear, simple operation, reliable;
* one key clear zero, ** correct;
* one-key correction, with standard weights attached at random, accurate and rapid;
* small error caused by the instrument itself can effectively control various errors in the measurement process;
* use the platinum panel method or the platinum loop method to connect to the computer, and choose the real-time curve software:
It can clearly show the rise or fall curve of tension caused by the presence of surfactant over time.
Can display the curve and time of two different density liquid interface from low to * high tension value, such as oil/water interface tension value.
* sample thermostatic cup can be selected, external thermostatic tank can control the temperature of the measured liquid.
* easy to operate.
Technical parameters:
Model BZY - 4 b
Measuring method plate (or ring)
Measuring range (mN/m)0~200
* small resolution (mN/m)0.01
Standard error (mN/m)±0.02(secondary distilled water at 20℃)
Repeatability (mN/m) + / - 0.02
Display mode LCD
Platform lifting mode manual: fast and fine tuning of the second gear
Signal output interface RS232C
Power supply voltage AC220V±10V
Overall dimension (mm)300×290×400
Net weight of 7 kg
Synchronous curve software: provide a set of curve software free of charge, through the installation program to the computer, you can simultaneously display the curve graph of tension value, data and time. Data can also be saved for customer inquiry.
Bzy-4b manual table/interface tensiometer, manual surface tensiometer
Application field
The basic function of tensiometer is to test the surface tension of liquid and liquid-liquid interfacial tension. Surfactants are widely used in all walks of life. Surfactants have emulsification, solubilization, decontamination, defoaming and other functions. Now the main application fields are introduced as follows:
Serial number application field purpose
1. Oil-water interface test in petrochemical industry; Oil product control; Determine the aging degree of running oil; Quality control of flooding fluid
Development of printing ink formula, wetting and adhesion of ink to printing substrate, quality control of pigment dispersion fountain solution, product development and quality control
3 paint, paint industry pigment dispersion, coating film on the substrate runing and adhesion coating leveling, emulsion stability
4. In the pharmaceutical industry, yao industry should improve the dispersing, emulsifying and wetting ability of drugs, optimize the formula and improve the effect of drug use
Analysis of surfactant emulsification, volume increase, decontamination, quality study of surfactant and concentration selection in detergent industry
6. The wettability of electroplating solution on the substrate in the electroplating industry, to prevent xx, dent and other defects, and to control the quality of process drawings
Analysis of dispersibility, stability, wettability, volume increasing, thickening, dispersion and emulsification of suspension agents and emulsifiers in cosmetic industry.
Analysis of wettability of fuel in textile industry, analysis of textile finishing liquid formula optimization
Food industry raw material surface finishing analysis, wettability analysis, packaging layer surface finishing analysis
10 water treatment industry water purification and sewage treatment, etc
Quality control of transformer oil, insulation oil and aging degree analysis of operating oil in power industry
Wettability, adsorption and degradation analysis of bioengineering polymer materials, and biological material engineering
13 CMC determination of surface materials in the institute; Development and research of new surfactant;
Development of surfactant application field, surface adsorption theory research, surface treatment technology development, etc
Applicable standards
Tensiometer is applicable to the following standards
JB/ t9388-2002 interface tensiometer conditions
GB/ t6541-86 determination of oil-water interface tensiometer for petroleum products (ring method)
Iso1409-1995 determination of plastic rubber polymer dispersion and latex surface finishing
GB/ t22237-2008 determination of surfactant surface tensiometer
Gb11278-89 determination of critical micelle concentration of anionic and nonionic surfactants (ring method)
GB/ t18396-2001 determination of surface tension by natural emulsion ring method
Determination of surface tension of synthetic rubber
Standard for testing liquid tension
Surface tensiometer/contact Angle with standard configuration:
Host 1 alcohol lamp 1
Platinum plate 1 tweezers
Glassware 2 sets of operation manual 1
Standard weights 1 synchronous real-time curve software 1 set