Ininge Compliance Tester
Instrument characteristics
This equipment is the testing equipment to test the product performance of the manufacturer.Composed of programmable controller, touch screen, force value sensor, transmission device, airborne printer, etc., it provides menu display in Chinese and English, with automatic operation test mode for various parameters of man-machine dialogue setting.In addition, the production unit, production batch machine input, so that the test results more standardized.Information security adopts three-level password to make information safe and reliable.Test control range includes: nominal capacity, core rod displacement, printing setting, testing, uplink, downlink, time, calibration, verification and other function setting.The print test can display test load, sliding data (starting force, average force, zui high thrust) in real time.To automatically judge the test results, the automatic beep alarm is activated, and the printer will print out the test data and results for analysis.
Test principle:
To enable the syringe to produce a specific hydraulic pressure, inject liquid into the entire syringe, record the liquid volume, and then measure the syringe compliance (i. e., the syringe nominal capacity changes when the internal hydraulic pressure is applied).
technical parameter:
Operation interface: Simplified Chinese / English
Test criteria: GB 15810-2019, YY / T 0573.2-2018, GB9706.27-2015, ISO7886-1:2017
Test item requirements: For the tested syringe with a nominal capacity of less than 50 mL, use a 1 mL or 2 mL pressurized syringe.For tested syringes with a nominal capacity of 50 mL and above, a 5 mL pressurized syringe was used.Steamed memory water meets the requirements of tertiary water in GB / T 6682.
test method:
1 Clean the tested syringe and inject steam memory water (B.2.2) Until the nominal capacity discharges all air from the system.
2 Connect the tested syringe and the test instrument (B.2.1), Hold the core rod firmly so that it can not move in the coat.
3 The tested syringe is isolated from the pressurized syringe and the pressure gauge using a three-way valve.
4 Apply test pressure given to Table 2 to the liquid system.
5 Note the maximum displacement volume in the pressurized syringe when each test pressure is reached.
6 Connect the measured syringe to the pressurized syringe and the pressure gauge using a three-way valve.
7 The volume difference recorded in each test pressure was calculated and recorded as the compliance of the tested syringe under this pressure.
Test rate: 0-100mm / min Error range: ± 1mm / min; (the test speed can be set by software)
Nominal capacity: 0.1ml~200 ml, all specifications of arbitrary input.
Product net weight: 15kg
Overall Dimensions: 430290400 (mm)
Power supply: AC90V-240V / 50Hz (adaptive wide voltage)
Complete machine power: 70W
Programmable controller: PLC / ARM
Touch screen: 7-inch nylon pass color touch screen K600 + kernel / dot matrix 65 color 800 * 480 resolution
Sensor: High-precision force value sensor
Force measuring mechanism: built-in
Printer: an airborne needle printer